Artigo Científico

Cutoff levels for newborn screening of 21-OH deficiency in a Brazilian metropolitan area

Publicado em: 2025

Autores

  • Kallianna Paula Duarte Gameleira
    Escola Superior de Ciências da Saúde (ESCS), Programa de Pós-Graduação em Ciências da Saúde, Brasília, DF, Brazil; Secretaria de Saúde do Distrito Federal, Serviço de Referência em Triagem Neonatal do Hospital de Apoio de Brasília, Brasília, DF, Brazil; Faculdade de Medicina, Escola Superior de Ciências da Saúde (ESCS), Brasília, DF, Brazil. Electronic address: kallianna@gmail.com.
  • Juliana de Vasconcellos Thomas
    Escola Superior de Ciências da Saúde (ESCS), Programa de Pós-Graduação em Ciências da Saúde, Brasília, DF, Brazil; Secretaria de Saúde do Distrito Federal, Serviço de Referência em Triagem Neonatal do Hospital de Apoio de Brasília, Brasília, DF, Brazil; Faculdade de Medicina, Escola Superior de Ciências da Saúde (ESCS), Brasília, DF, Brazil. Electronic address: julianavthomas@gmail.com.
  • Vitor Guilherme Brito de Araújo
    Secretaria de Saúde do Distrito Federal, Serviço de Referência em Triagem Neonatal do Hospital de Apoio de Brasília, Brasília, DF, Brazil. Electronic address: vitaraujo@gmail.com.
  • Cláudia Vicari Bolognani
    Escola Superior de Ciências da Saúde (ESCS), Programa de Pós-Graduação em Ciências da Saúde, Brasília, DF, Brazil; Faculdade de Medicina, Escola Superior de Ciências da Saúde (ESCS), Brasília, DF, Brazil. Electronic address: claudiavicari@gmail.com.
  • Sérgio Eduardo Soares Fernandes
    Faculdade de Medicina, Escola Superior de Ciências da Saúde (ESCS), Brasília, DF, Brazil. Electronic address: sergioesfernandes@gmail.com.
  • Fábio Ferreira Amorim
    Escola Superior de Ciências da Saúde (ESCS), Programa de Pós-Graduação em Ciências da Saúde, Brasília, DF, Brazil; Faculdade de Medicina, Escola Superior de Ciências da Saúde (ESCS), Brasília, DF, Brazil; Universidade de Brasília (UnB), Programa de Pós-Graduação em Ciências da Saúde, Brasília, DF, Brazil. Electronic address: ffamorim@gmail.com.

Resumo

To evaluate the accuracy of neonatal 17-hydroxyprogesterone (N17OHP) levels adjusted for birth weight (BW) and time of the sample collection (TC) and propose optimized cutoff values to improve the effectiveness of newborn screening tests for congenital adrenal hyperplasia (CAHNBS) programs, utilizing a comprehensive dataset encompassing all newborn screening tests for 21-hydroxylase deficiency (21OHD) conducted over a decade in a Brazilian metropolitan region. A cross-sectional study analyzed all CAHNBS tests from newborns aged 2 to 7 days in the Federal District, Brazil, from January 2012 to September 2022. The accuracy of cutoff values based on the 99.5th percentile (99.5P) for BW and TC was compared to the CAHNBS program of São Paulo and a threshold of ≥20 mg/dL. New cutoff values were proposed to enhance screening effectiveness. Among the 340,291 newborns screened, CAH-21OHD was confirmed in 11 cases. The N17OHP cutoff in this sample reduced false positives for neonates ≤ 2500 g but increased them for those > 2500 g The proposed cutoff values based on 99.5P from the sample for neonates ≤ 2500 g, combined with a fixed cutoff ≥ 20 mg/dL for those > 2500 g, showed superior specificity (99.83 %, 95 % CI: 99.81-99.84 %), LR+ (579.16, 95 % CI: 524.23-627.87), PPV (1.84, 95 %CI: 1.70-1.99), and accuracy (99.83 %, 95 %CI: 99.81-99.84 %) than prior criteria. The proposed 17OHP cutoff strategy effectively reduced false positives, improving specificity, LR+, PPV, and accuracy Thus, it optimized CAHNBS programs while minimizing unnecessary costs and parental distress.

Utilizamos cookies para melhorar sua experiência. Ao navegar, você concorda com nossa Política de Privacidade. Ler Política

Painel de Acessibilidade

Ajuste sua experiência de navegação

LIBRAS

ASSISTÊNCIA VISUAL

Tamanho da Fonte

100%